FilePower (Optika)

The FilePower batch output format produces single-page TIFF images, a Data file and an Action file with the command IMPORT in its command field. This allows batches processed by the FilePower batch output format to be imported into FilePower, using FPtransact for Fpmulti. The following describes the output produced by Capture Software when using the FilePower batch output format. 

The FilePower batch output format will create a subdirectory in the root export directory (i.e., Path field in the Application setup - Output tab). This directory will have the same name as the current Capture Software batch name. The TIFF images will be placed in this directory, and will be named starting with 00000000.tif and progressing up to 99999999.tif.  
The Data file will be placed in the batch subdirectory as well. The name of the Data file is user-definable, but it will always have a file extension of .lst. The default name is DATAFILE. The Action file can either be placed in the batch subdirectory or the root export directory. The Action file will always have a file extension of .tra. If placed in the batch subdirectory, the Action file's name is user-definable with a default name of ACTFILE. If placed in the root export directory, the Action file will have the same name as the Capture Software batch name. For example, if a FilePower application's Action file is created in the root export directory, and the batch named BATCH029 is processed, the Action file will be named BATCH029.TRA.

In the Application Setup - Output tab, click on Setup to define the name of the Data and Action files, the FilePower Application Name and Subfolder Name, the Delete Object, Full Text Object and Full Text Verify Object options, and the Data file field delimiter. 

The Data and Action file names, Application Name and Subfolder Name must all be defined before a batch can be processed. When changing their names, it is not necessary to enter the file name extensions and doing so will cause the extension to appear twice at the end of the name. Application Name and Subfolder Name have no default values therefore they must be given values prior to processing a batch.  The maximum length of the Data file name is 255 characters (this includes not only the name of the Data file as it is entered in the setup dialog, but also the full path to the batch output directory). The maximum length of the Application Name is 15 characters and the maximum length of the Subfolder Name is 30.

The Delete Object option has a default value of 1 (check box in setup dialog is checked), the Full Text Object option a default value of 0 (check box is unchecked), and the Full Text Verify Object a default value of 0 (check box is unchecked).  Note that neither of the two Action file fields Command and Object Type are user definable; the Command field is always IMPORT and the Object Type field is always TIFF.

The Data file field delimiter has a default value of '~' (i.e., a tilde).  Note that selecting a ' or a " as a delimiter causes two delimiters to be written between each data file field (i.e., a single quote field delimiter will always be written as '' and a double quote field delimiter will always be written as "").

FilePower has two types of index fields, Folder and Document. All declared Capture Software batch index fields will be written to the Data file as Folder index fields in the order that they are declared in Capture Software (i.e., first batch index field in Capture Software is written as the first Folder index field to the Data file). A maximum of four Folder index fields can be defined. As a result, declaring more than four Capture Software batch index fields will result in an error when processing the batch.

All declared Capture Software document index fields are written, by default, to the Data file as Document index fields in the order that they are declared in Capture Sofware. It is possible, however, to have the Capture Software Document index fields written to the Data file as Folder index fields. This can be done by clicking on the "Folder/Document Index Field Assignment" button in the FilePower (Optika) batch output Setup dialog.

In the "Folder/Document Index Field Assignment" dialog, all Capture Software document index fields will be listed. Next to each field name are two radio buttons, labeled Folder and Document. Whichever button is selected will result in that field being written to the appropriate section of the Data file. If document index fields will be written to Folder index fields in the Data file, they will be written in the order that they are declared in Capture Software Application Setup (Index tab) and will come after any batch index fields. The total number of Capture Software index fields (batch or document) that can be written to Data file Folder index fields must not exceed four. Likewise, the total number of Capture Software document index fields that can be written to Data file Document index field must also not exceed four. If more than four are assigned, an error will occur either at batch process time or when attempting to exit the FilePower (Optika) batch output Setup dialog.